[VPLEX]在兩臺(tái)Local之間做數(shù)據(jù)遷移
說明:
VPLEX不支持跨獨(dú)立VPLEX群集的XCopy。
VPLEX只支持在Metro配置中夸兩個(gè)集群的XCopy。
?
解決問題:
1.????? 在VPLEX上禁用storage-view的XCopy
2.????? 在ESXi主機(jī)上啟用加速鎖定(可選)
?
解決方法:
1.????? 通過SSH登錄到VPLEX,進(jìn)入vplexcli模式下,將目錄切換到/clusters/cluster-1/exports/storage-views下查看storage-view
VPlexcli:/> cd /clusters/cluster-1/exports/storage-views/?????????????????????????????????????????????????????????????????????????
VPlexcli:/clusters/cluster-1/exports/storage-views> ls????????????????????????????????????????????????????????????????????????????
VMware
進(jìn)入你的storage-view,并執(zhí)行關(guān)閉XCopy命令
VPlexcli:/clusters/cluster-1/exports/storage-views> cd VMware/????????????????????????????????????????????????????????????????????
VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> set xcopy-enabled false?? ??
?
查看更改效果:
VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> ll?????????????????????????????????????????????????????????????????????
Name????????????????????? Value
------------------------? ---------------------------------------------------------------------------------------
caw-enabled?????????????? true
controller-tag??????????? -
initiators??????????????? ESXi1821041_2, ESXi1821041_3, ESXi1821042_2, ESXi1821042_3, ESXi1821061_2,
????????????????????????? ESXi1821061_3, ESXi1821062_2, ESXi1821062_3, ESXi1821063_2, ESXi1821063_3, ... (104
????????????????????????? total)
operational-status??????? ok
port-name-enabled-status? P0000000047A03A92-A0-FC00,true,ok, P0000000047A03A92-A0-FC01,true,ok,
????????????????????????? P0000000047A03A92-A0-FC02,true,ok, P0000000047A03A92-A0-FC03,true,ok,
????????????????????????? P0000000047A03B8E-A0-FC00,true,ok, P0000000047A03B8E-A0-FC01,true,ok,
????????????????????????? P0000000047A03B8E-A0-FC02,true,ok, P0000000047A03B8E-A0-FC03,true,ok,
????????????????????????? P0000000047B03A92-B0-FC00,true,ok, P0000000047B03A92-B0-FC01,true,ok, ... (16 total)
ports???????????????????? P0000000047A03A92-A0-FC00, P0000000047A03A92-A0-FC01, P0000000047A03A92-A0-FC02,
????????????????????????? P0000000047A03A92-A0-FC03, P0000000047A03B8E-A0-FC00, P0000000047A03B8E-A0-FC01,
????????????????????????? P0000000047A03B8E-A0-FC02, P0000000047A03B8E-A0-FC03, P0000000047B03A92-B0-FC00,
????????????????????????? P0000000047B03A92-B0-FC01, ... (16 total)
virtual-volumes?????????? (0,device_CLARiiON0109_Y_VNX_LUN_27_1_vol,VPD83T3:6000144000000010b03a92b11c792c7a,3T),
????????????????????????? (1,device_CLARiiON0109_Y_VNX_LUN_26_1_vol,VPD83T3:6000144000000010b03a92b11c792c79,3T),?????????????????????? (2,device_CLARiiON0109_Y_VNX_LUN_25_1_vol,VPD83T3:6000144000000010b03a92b11c792c78,3T), (3,device_CLARiiON0109_Y_VNX_LUN_24_1_vol,VPD83T3:6000144000000010b03a92b11c792c77,3T), (4,device_CLARiiON0109_Y_VNX_LUN_23_1_vol,VPD83T3:6000144000000010b03a92b11c792c76,3T), (5,device_CLARiiON0109_Y_VNX_LUN_22_1_vol,VPD83T3:6000144000000010b03a92b11c792c75,3T), (6,device_CLARiiON0109_Y_VNX_LUN_21_1_vol,VPD83T3:6000144000000010b03a92b11c792c74,3T), (7,device_CLARiiON0109_Y_VNX_LUN_20_1_vol,VPD83T3:6000144000000010b03a92b11c792c73,3T), (8,device_CLARiiON0109_Y_VNX_LUN_19_1_vol,VPD83T3:6000144000000010b03a92b11c792c72,3T), (9,device_CLARiiON0109_Y_VNX_LUN_18_1_vol,VPD83T3:6000144000000010b03a92b11c792c71,3T),
????????????????????????? ... (57 total)
write-same-16-enabled???? true
xcopy-enabled???????????? false
最后一行顯示已經(jīng)關(guān)閉。
注:兩臺(tái)VPLEX Local都需要修改
?
2.????? 在受影響的ESXi主機(jī)上,啟用加速鎖定但禁用加速移動(dòng)(XCOPY)。
用戶可以選擇性地禁用ESXi主機(jī)上不支持的基元,而不是禁用VAAI中的所有內(nèi)容。 要更具體地了解這些變化:
HardwareAcceleratedLocking = OK; enable (atomic test and set)
HardwareAcceleratedMove = Not OK; leave disabled (clone blocks, full copy, xcopy)
HardwareAcceleratedInit = OK; enable (zero blocks, write same)
?